| Please note: we are not a reseller of instruments |
| GC/MS semi-volatiles |
back to top |
| Hewlett-Packard 5890 Series II Gas Chromatograph equipped with a 5972 Mass Selective Detector and a 7673C Autosampler Data System |
| Hewlett-Packard 5890 Series II Gas Chromatograph with Electronic Pressure Control equipped with a 5971B Mass Selective Detector and a 7673 Automatic Injector |
| Hewlett-Packard 5890 Series II Gas Chromatograph with Electronic Pressure Control equipped with a 5971B Mass Selective Detector and a 7673A Automatic Injector |
| Hewlett-Packard-GCD Gas Chromatograph with Electronic Pressure Control with an upgraded 5972 Mass Selective Detector and a 7673B Automatic Injector |
| GC semi-volatiles |
back to top |
| Hewlett-Packard 5890A Gas Chromatograph with Dual Split/Splitless Injectors and Dual Flame Ionization Detectors equipped with a 7673A Automatic Injector |
| Hewlett-Packard 5890 Gas Chromatograph with a Universal Injector and a Flame Ionization Detector and an Electron Capture Detector equipped with a 7673A Automatic Injector |
| Varian 3400 Gas Chromatograph with an Electron Capture Detector and a Universal Injector equipped with an 8200 Autosampler |
| Varian 3400 Gas Chromatograph with an Electron Capture Detector and a Split/Splitless Injector equipped with an 8200 Autosampler |
| Varian 3400 Gas Chromatograph with an Electron Capture Detector and a Universal Injector equipped with an 8100 Autosampler |
| Hewlett-Packard 5890 Gas Chromatograph equipped with a Flame Ionization Detector and a 7673A Automatic Injector |
| HPLC |
back to top |
| Applied Biosytems 150A Dual Channel High Performance Liquid Chromatography System with Ultraviolet and Fluorescence Detectors and a WISP 710B Autosampler |
| GC/MS volatiles |
back to top |
| Hewlett-Packard 5890 Series II Gas Chromatograph with Electronic Pressure Control and a 5972 Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Centurion Dual Mode Autosampler |
| Hewlett-Packard 5890 Series II Gas Chromatograph with Electronic Pressure Control and a 5971A Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Dynatech PTA Autosampling System |
| Hewlett-Packard GCD Gas Chromatograph with Electronic Pressure Control with an upgraded 5972 Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Centurion Dual Mode Autosampler |
| Hewlett-Packard 5890 Gas Chromatograph with a 5971A Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Dynatech PTA Autosampling System |
| Hewlett-Packard-GCD Gas Chromatograph with Electronic Pressure Control with an upgraded 5972 Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Dynatech PTA-30 Autosampling System |
| GC volatiles |
back to top |
| Varian 3300 Gas Chromatograph with O.I. 430 Photo Ionization Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Dynatech PTA-30 W/S Water and Soil Autosampling System. |
| Varian 3400 Gas Chromatograph with Dual Varian Flame Ionization Detectors |
| Varian 3400 Gas Chromatograph with Varian Flame Ionization Detector |
| Wet chemistry group |
back to top |
| Lachat QuikChem® 8000 Instrument with XYZ Sampler |
| Mettler DL-21 Auto-Titrator with Probes for Alkalinity and Chloride Analyses |
| Kontes Midi Cyanide Distillation Unit |
| Dionex DX500 Ion Chromatograph System |
| Perkin Elmer 1650 FT-IR Fourier Transform Infra-Red Spectrophotometer |
| Two Milton Roy Spectronic 21 Digital Spectrophotometers |
| O.I. Corporation Model S3000 Flow Analyzer with a Model 5027 Autosampler |
| O.I. Corporation Model 700 Total Organic Carbon Analyzer with Autosampler |
| SpectronicTM Genesys 5 UV/Vis Spectrophotometer |
| YSI5100 Dissolved Oxygen Meter |
| Orion 830A Dissolved Oxygen Meter |
| Orion Model 122 Conductivity Meter |
| YSI Model 3200 Conductivity Meter |
| Euroglass 1200 AOX Analyzer |
| Pensky-Martens TS-74745 AP-9 Flash Point Tester |
| Konelab Aqua 20 Discrete Analyzer |
| Horizon SPE-DEX 1000XL Extractor |
| Metals group |
back to top |
| Perkin Elmer Sciex Elan 6100 Inductively Coupled Plasma Mass Spectrometer |
| Jobin Yvon Ultima 2 Inductively Coupled Plasma Atomic Emission Spectrometer with AS421 Autosampler |
| Perkin Elmer AAnalyst 600 Atomic Absorption Spectrophotometer with Zeeman Background Correction |
| Leeman Labs PS-200 Automated Mercury Analyzer - Cold Vapor Atomic Absorption |
| Millennium Merlin Atomic Fluorescence Low-Level Mercury Analyzer |
| Field sampling |
back to top |
| Grundfos Low Volume Well Pump Submersible |
| Isco Model 2910 Wastewater Sampler |
| Two Isco Model GLS Wastewater Samplers |
| Isco Model 3700 Wastewater Sampler |
| Stainless Steel Hand Auger with Four (4) Five Foot Extensions |
| Two Conductivity-Type Well Depth Measuring Devices |
| Hanna Instruments: pH, Temperature, Conductivity, TDS Meter |
| Hanna Instruments: Field Turbidimeter |
| Mobile laboratory |
back to top |
| Sixteen Foot Custom Designed Trailer with High Purity Gas Manifolds, Refrigerator, Air Conditioning, Heating and Sink |
| Two Mettler BD 202 Balances |
| Two 5000 Watt Honda Generators |
| Hewlett-Packard GCD Gas Chromatograph with Electronic Pressure Control with an upgraded 5972 Mass Selective Detector coupled with a Tekmar LSC-2000 Purge and Trap Concentrator and a Dynatech PTA-30 Autosampling System |
| Air quality |
back to top |
| Apex Instrument Complete EPA Method 5 Stack Sampling |
| Hot Wire Anamometer |
| Olympus BH-2 (BHSP) Polarized Light Microscope |
| Olympus CH-2 Phased Contrast Microscope |
| Four SKC Personal Air Sampling Pumps |
| Drycal DC-Lite Primary Flow Meter |
| High Volume Air Sampling Pump |
| Bacharach Electronic Gas Analyzer for Carbon Monoxide |
| Bacharach Electronic Combustion Gases Meter |